Intraocular pressure change after myopic laser in situ keratomileusis as measured on the central and peripheral cornea

, PhD, MD, , MD, , PhD MD, , MM & , MM
Pages 421-426
Received 24 Jul 2011
Accepted 21 Oct 2011
Published online: 15 Apr 2021
 

Background:  Laser in situ keratomileusis (LASIK) leads to inaccurate measurement of intraocular pressure (IOP). This study aimed to determine the efficacy and reliability of IOP measurement on the peripheral cornea after LASIK.

Methods:  The IOP was measured in 52 eyes of 26 subjects before LASIK and one week and one month after LASIK using non‐contact tonometry. The measurements were made on the central and peripheral cornea and the results were subjected to statistical analysis.

Results:  The mean measured IOP on the central cornea was decreased by 6.425 ± 2.544-mmHg at one week and 5.752 ± 3.863-mmHg at one month post‐operatively. The mean IOP measured on the peripheral cornea was decreased by only 0.921 ± 2.054-mmHg at one week post‐operatively. Most notably, the mean IOP measured on the peripheral cornea was increased by only 0.158 ± 2.979-mmHg at one month post‐operatively with no statistical significance (p > 0.05). Furthermore, a linear regression of ablation depth versus change in IOP measured on the central cornea was demonstrated, but the peripheral IOP did not display such a statistically significant correlation with the depth of ablation at both one week and one month after operation.

Conclusion:  The IOP measured on the peripheral cornea is closer to the actual IOP. Therefore, it is more accurate and reliable to measure IOP on the peripheral cornea than on the centre after LASIK.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
EUR 47.00 Add to cart

Purchase Issue

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
EUR 63.00 Add to cart

* Local tax will be added as applicable
 

Related research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.