313
Views
5
CrossRef citations to date
0
Altmetric
Original Articles

Effects of a phase change cooling garment during exercise in the heat

, , , &
Pages 1065-1073
Published online: 07 Jul 2017
 

Abstract

The purpose of our study was to examine the physiological, perceptual, and performance effects of wearing a phase change cooling garment (CG) during an interval exercise routine in the heat. Sixteen male participants (age 23 ± 3 years, ht 1.76 ± 0.11 m; wt 78.5 ± 11.2 kg; body fat 15.2 ± 5.8%) completed two trials (one with phase change inserts, CG, and one control without inserts) consisting of two submaximal exercise portions separated by 5-minute seated rest, and a final maximal effort performance bout. Each submaximal bout involved 30 seconds or 1 minute of muscular endurance and agility exercises and 5 minutes of treadmill jogging and step-ups. The performance bout included 30 seconds or 1 minute of muscular endurance and agility exercises, with participants completing as many repetitions as possible, followed by a 15-minute recovery (active and passive). Rectal temperature (Tre) and heart rate were not different between trials, however change in Tre from baseline was improved during 10 and 15 minutes of recovery with the CG (P < .05). Mean skin temperature was lower using the CG vs control throughout the trial (P < .05). Thermal sensation was lower when using the CG compared to control (P < .001). There were no differences in any outcomes of the performance exercises (P > .05). These findings indicate that the continuous use of a CG during an interval style workout in the heat provides improvements in thermal sensation, however, only minimal thermophysiological benefits, and no performance augmentation.

Acknowledgements

The authors would like to thank Christopher Reed, Noel Belcher, Ryan Dawson, Carlaine Myers, and Mikaila Davis for their assistance with collection of the data for this protocol. Further, the authors would like to thank PreventaMed Inc for providing the phase change inserts and Sweat It Out for providing the compression garments. Neither PreventaMed Inc nor Sweat It Out were involved in the collection, analysis, or interpretation of data in this study. No external funding was provided for this project.

Disclosure statement

No potential conflict of interest was reported by the authors.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 50.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 285.00 Add to cart

* Local tax will be added as applicable
 

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.